Photophysical lock-in detection enables background-free upconversion emission imaging.

Bagheri N, Wang C, Guo D, Lakshmanan A, Zhu Q, Chen X, Ghazyani N, Zhan Q, Sotiriou GA, Liu H, Widengren J

Light Sci Appl 15 (1) - [2026-09-07; online 2026-09-07]

Lanthanide-based upconversion nanoparticles (UCNPs) have attracted considerable attention in biomedical applications, due to their anti-Stokes shifted emission enabling autofluorescence-free signal detection. However, residual excitation light can still interfere with their relatively weak emission signals. While commonly used lock-in detection can distinguish weak signals from substantial random background, concurrently modulated residual excitation light is not eliminated. This remains a challenge, particularly under demanding experimental conditions. Here, we propose a photophysical lock-in detection (PP-LID) approach based on the discovery that UCNPs can act as frequency mixers in response to intensity-modulated excitation. Particularly, excitation modulated at multiple base frequencies can generate additional spectral components at the beat frequencies (BFs) between the base modulation frequencies. These signals are resolvable by frame-rate-limited cameras, devoid of ambient and residual excitation light, and can be adapted through nanoparticle engineering. Extracting BF signals by PP-LID thus provides a strategy to significantly enhance signal-to-background conditions in UCNP-based bioimaging and biosensing.

PubMed 42706226

DOI 10.1038/s41377-026-02414-2

Crossref 10.1038/s41377-026-02414-2

pmc: PMC13550578
pii: 10.1038/s41377-026-02414-2